Solutions for renewable energy

Renewable energy

Whether they provide photovoltaic, wind or water power, the number of power generation plants using renewable energy continues to grow. The operators of these plants attach great importance to efficiency and economy. Only by means of proper system solutions for the control and monitoring of power generation can competitive efficiency be achieved. Only a high level of efficiency can create the economic basis for replacing electricity from fossil fuels. In addition, it is important that safety-related issues are considered.

Smart motorstarter UG 9256

• According to IEC/EN 60 947-4-2
• To reverse 3 phase motors from 90 W to 750 W resp. 550 W to 4 kW
at AC 400 V
• 2-phase softstart
• max. 4 potentiometer für setting of starting torque, deceleration torque,
softstart /-stop, overcurrent limit or rated motor current
• 4 LEDs for status indication
• Reversing with relays...

Latching relay MK 8852

• According to IEC/EN 61 810-1
• Setting input A1 - A2
• Reset input A3 - A2
• Storage function
• Switch position indication
• Manual operation
• Width 22.5 mm

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• With connection facility of an external coupling device RP 5898
for voltages up to 1000 V
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm):...

Locating current injector RR 5886

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current...

Latching relay AD 8851

• According to IEC/EN 61 810-1
• Manual operation possible
• Contact position indication via control lever
• max. 4 NC contacts, 4 NO contacts
• Width 45 mm

Insulation monitor RN 5897/300

• Insulation monitoring according to IEC/EN 61557-8
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 1 MΩ:
• Setting range of 2nd response value (Alarm): 10 kΩ … 250 kΩ
• 2 changeover contacts für...

Insulation fault locator RR 5887

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
•...

Voltage and frequency monitor acc. to VDE-AR-N 4105 RP 9810

• Certificate of conformity (test certificate) of the BG ETEM
acc. to VDE-AR-N 4105
• Following DIN V VDE V 0126-1-1
• According to DIN EN 60 255-1
• Can be used according to EEG 2012 and SysStabV
• Voltage and frequency monitoring for generator sets >30 kVA on
public grid, as option also for ≤ 30kVA
• Fail-safe because...

Voltage and frequency monitor RP 9811

• Certificate of conformity (test certificate) of the BG ETEM
• Acc. to VDE-AR-N 4105, DIN VDE 0126-1-1, BDEW-directive,
CEI-0-21
• Acc. to DIN EN 60 255-1
• Can be used according to EEG 2012 and SysStabV
• Voltage and frequency monitoring for generator sets
• Fail-safe 2-channel structure
• Monitoring of the section...

Insulation monitor LK 5896

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g.
for mains couplings
• 1 changeover contact each for prewarning and alarm
• 3. output relay for signalling wire break and device faults
• Prewarning...

Insulation monitor LK 5895

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• Measuring circuits can be disconnected via control terminals, e.g.
for mains couplings
• 1 changeover contact each for prewarning and alarm
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm...

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output...