Solutions for building automation

Building automation

The demands on modern building automation systems are increasing all the time. The focus is on the control, convenience and intelligent linking of systems and their communication options. As complexity increases, the need for the greater surveillance and transparency of electrical building equipment is also growing in the form of centralized and decentralized information sources that display status, operation and error information.

Solid-state relay / contactor PH 9260

• AC semiconductor relay / -contactor
• According to IEC/EN 60947-4-3
• Load current up to 125 A, AC 51 with I2t up to 18000 A2s
• Switching at zero crossing
• As option switching at voltage maximum
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
•...

Solid-state relay / contactor, 2-poles PH 9260.92

• AC solid-state relay / -contactor
• According to IEC/EN 60947-4-3
• As option load current up to 2 x 32 A or 2 x 48 A
• As option with hight I²t up to 6600 A²s
• Load voltages up to AC 480 V
• 2 anti-parallel thyristors for each pole
• DCB technology (direct bonding method) for excellent
heat transmission...

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator...

Solid-state relay / contactor for resistive load PK 9260

• AC semiconductor relay / -contactor
• PK 9260/_ _ _ according to IEC/EN 62314
PK 9260/_ _ _ / _ _ according to IEC/EN 60947-4-2 and -4-3
• Load current up to 88 A, AC-51
• Switching at zero crossing for resistive loads
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission...

Interface relay / input-output IK 8701

• According to IEC/EN 61 810-1
• Optionally contacts with up to a maximum 4 changeover contacts
• High thermal current Ith
• Pushbutton for manual actuation of the contact
• Operating position display
• Optionally without manual actuation and an operating position display
• Optionally for 2-wire initiator activation
•...

Interface relay / input-output IL 8701

• According to IEC/EN 61 810-1
• Optionally contacts with up to a maximum 4 changeover contacts
• High thermal current Ith
• Pushbutton for manual actuation of the contact
• Operating position display
• Optionally without manual actuation and an operating position display
• Optionally for 2-wire initiator activation
•...

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: