Solutions for drive and conveyor technology

Drive and conveyor technology

Wherever something has to be moved, whether it is in the field of economical material flow control or in the accurate positioning, in rapidly bridging large distances or in the case of accurate handling in confined spaces: The high reliability of the drive and conveyor technology is a prerequisite for continuous productivity and efficient process flow. Besides the mechanical and electrical drive components, reliable drive control and monitoring also plays an important role. In addition, protection must be provided against hazardous movements in accordance with the Machinery Directive and other safety requirements.

Locating current injector RR 5886

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the insulation fault locator RR 5887 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1 (VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• External control via insulation monitor possible
• Positive and negative test current...

Radio controlled safety module UH 6900

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Machine directive 2006/42/EG
• DIN EN 574: Safety of machinery - Two-hand control devices -
• DIN EN 300 220: Electromagnetic compatibility and...

Electronic Motor Brake Relay BI 9034

• According to IEC/EN 60947-4-2
• For all single and 3-phase asynchronous motors
• DC-brake with one way rectification up to max. 60 A
• Controlled by microcontroller
• Easily fitted to existing installations
• Wear free and maintenance free
• Integrated braking contactor
• DIN-rail mounting
• Adjustable braking...

Insulation monitor RN 5897/010

• Insulation monitoring according to IEC/EN 61557-8
• Trigger output for insulation fault locating system
• 2 separate adjustable response thresholds
(using e.g. for pre-Alarm and Alarm)
• Setting range of 1st response value (Pre-Alarm): 20 kΩ … 2 MΩ
• Setting range of 2nd response value (Alarm): 1 kΩ...

Insulation fault locator RR 5887

• Insulation troubleshooting in DC, AC and mixed IT systems in connection with the locating current injector RR 5886 according to DIN EN 61557-9 (VDE 0413-9):2009 and DIN EN 61557-1
(VDE 0413-1)
• Insulation coordination according to IEC 60664-1
• Connection of max. 4 or 8 differential current transformers depending on the design
•...

Electronic Motor Brake Relay BA 9034N

• According to IEC/EN 60947-4-2
• For all single and 3-phase asynchronous motors
• DC-brake with one way rectification up to max. 32 Aeff
• Controlled by microcontroller
• Easily fitted to existing installations
• Wear free and maintenance free
• Integrated braking contactor
• DIN-rail mounting
• Adjustable...

Stand-still monitor LH 5946

• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508, IEC/EN 61511 and EN 61800-5-2
• Safe standstill detection on 3- and single-phase motors
• No external sensors necessary
• Independent of direction
• Broken wire...

Motor Brake Relay BI 9023

• nach IEC/EN 60 947-4-2
• DC brake with one way rectified brake voltage
• Suitable foe all squirrel cage motors
• Easy to fit also in existing circuits
• Wear- and maintenance free
• To mount on 35 mm DIN rail
• Adjustable brake current to 80 A
• Adjustable braking time 1 ... 20 s (others on request)
• 90 mm...

Motor Brake Relay BN 9034

• DC brake with one way rectifier up to 600 A
• Can be used on all asynchronous motors
• Easy to fit also into existing control circuits
• Wear and maintenance free
• Integrated braking contactor for devices up to 60 A
• Mounting on 35 mm DIN-rail for 25 A units
• Adjustable braking current
• With automatic...

Residual current monitor, Type B RN 5883

• According to IEC/EN 62 020, VDE 0663
• For AC and DC systems Type B, according to IEC/TR 60755
• To detect earth faults in grounded voltage systems
• 4 setting ranges from 10 mA to 3 A
• Manual reset, with alarm and pre-warning
• With adjustable switching delay
• Energized or de-energized on trip
• LED indicator...

Speed and frequency monitor UH 6937

• According to
- Performance Level (PL) e und category 4 to EN ISO 13849-1
- SIL-Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL 3) to IEC/EN 61508
- Safety Integrity Level (SIL) 3 to IEC/EN 61511
• Over-, underfrequency or window monitoring of single or
3-phase in AC systems
• Integrated user friendly frontside...

Motor Brake Relay GB 9034

• DC brake with one way rectifier up to 600 A
• Can be used on all asynchronous motors
• Easy to fit also into existing control circuits
• Wear and maintenance free
• Integrated braking contactor for devices up to 60 A
• Mounting on 35 mm DIN-rail for 25 A units
• Adjustable braking current
• With automatic...

Insulation monitor LK 5894

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 2 changeover contacts
• Prewarning threshold setting range: 20 kΩ ... 2 MΩ
• Alarm threshold setting range: 1 kΩ ... 250 kΩ
• Energized or de-energized on trip can be selected for output...

Insulation monitor UH 5892

• Insulation monitoring according to IEC/EN 61557-8
• Detection of symmetric and asymmetric insulation faults
• 1 changeover contact for alarm
• Fixed response value RAN: 50 kΩ, other on request
• Internal reset and test pushbutton
• External test and reset pushbutton can be connected
• LED indicator for auxiliary...

Insulation monitor IL 5880

• According to IEC/EN 61 557-8
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 10000 Hz
• Adjustable tripping value RAL of 5 ... 100 kΩ
• Monitors also disconnected voltage systems
• De-energized on trip
• Auxiliary voltage Measuring Circuit and output contacts are galvanically separated
• Manual...

Insulation monitor SL 5880

• According to IEC/EN 61 557-8
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 10000 Hz
• Adjustable tripping value RAL of 5 ... 100 kΩ
• Monitors also disconnected voltage systems
• De-energized on trip
• Auxiliary voltage Measuring Circuit and output contacts are galvanically separated
• Manual...

Insulation Monitor SP 5880

• According to IEC/EN 61 557-8
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 10000 Hz
• Adjustable tripping value RAL of 5 ... 100 kΩ
• Monitors also disconnected voltage systems
• De-energized on trip
• Auxiliary voltage Measuring Circuit and output contacts are galvanically separated
• Manual...

Insulation monitor MK 5880N

• According to IEC/EN 61 557-8
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
• Monitors also disconnected voltage systems
• Adjustable tripping value RALof 5 ... 100 kΩ
• De-energized on trip
• Auxiliary voltage, measuring circuit and output contacts are galvanically separated
• Manual...

Insulation monitor MH 5880

• According to IEC/EN 61 557-8
• For single and 3-phase AC-systems up to 0 ... 500 V and 10 ... 1000 Hz
• Monitors also disconnected voltage systems
• Adjustable tripping value RALof 5 ... 100 kΩ
• De-energized on trip
• Auxiliary voltage, measuring circuit and output contacts are galvanically separated
• Manual...

Insulation monitor RP 5888

• Increasing the availability of machines and plants
• For preventive maintenance
• According to IEC/EN 61 557-8
• With configurable analogue output for insulating value
• For three-phase and A.C. power systems with 0 ... 500 V and 10 ... 1000 Hz
• Adjustable alarm value for ground fault RAL of 5 k ... 5 MΩ
•...

Insulation monitoring relay motor windings BD 5877/241

• According to IEC/EN 61 557
• Setting range 200 kΩ to 2 MΩ
• LED indicators
• Output: 1 NO contact
• De-energized on trip
• Test button for function check
• Reset button
• Input for voltage detection
• Manual reset available by bridge
• Width 45 mm

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.