Solid state contactors and relays from DOLD are the first choice everywhere that high switching frequencies and cycles in the industry are needed. They conduct switching and control tasks especially efficiently in numerous applications in industrial and building technology. Their long service life due to wear-free switching is the reason for this. DOLD also has an innovative answer to the problem caused by switching with high load currents, the severe heating of solid state contactors and relays: the use of DCB processes (Direct Copper Bonding) optimises the heat dissipation in the power stage of the device and thus ensure the operational security of your system. Solid state conductors are also used in other applications such as heating, lighting, et cetera.
Please select required language:
Flyer, Solid-state relay / contactor PI 9260, File: pdf, File size 284 KB
Flyer, Solid state relay PH 9270, File: pdf, File size 209 KB
Flyer, Solid state relay PK 9260, File: pdf, File size 275 KB
Brochure, Product overview POWERSWITCH, File: pdf, File size 458 KB
Catalogue, Power electronics, File: pdf, File size 5 MB
Choose a product:
• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole models
• Load current up to 50 A
• For AC load up to 480 V
• Switching at zero crossing
• Protected by varistors
• As option temperature protection of the power semiconductors
with monitoring output
• Mounting on DIN-rail
• As option with...
• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole versions
• Load current up to 50 A at TU = 40° C
• For AC load up to 530 V
• Switching at zero crossing, optionally immediate switching
• Protected by varistors
• Mounting on DIN-rail
• As option with high I2t of the semiconductor for high...
• Analogue controller for accurate process temperature control
• Burst firing control of heaters
• Control input optional with DC 0 ... 10 V, DC 4 ... 20 mA, 0 ... 10 kΩ
• Reverse action operation possible
• Rated operational voltage range up to 480 V
• Rated operational current is up to AC 50 A
• Zero cross...
• AC solid-state relay / -contactor
• PK 9260/_ _ _ according to IEC/EN 62314
PK 9260/_ _ _ / _ _ according to IEC/EN 60947-4-2 and -4-3
• Load current up to 88 A, AC-51
• Switching at zero crossing for resistive loads
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission...
• According to IEC/EN 60 947-1, IEC/EN 60 947-4-2
• Switching at zero crossing
• To switch single-phase AC load up to 400 V
• Compensates voltage fluctuations of ± 20 %
• Load current up to 40 A
• Monitors:
- Undercurrent
- Overcurrent
- Interrupted load circuit
- monitors temperature to protect the power semiconductor
•...
• According to IEC/EN 60 947-4-2, IEC/EN 60 947-4-3
• 1-, 2- and 3-pole models
• Load current up to 50 A
• For AC load up to 480 V
• Switching at zero crossing
• Protected by varistors
• As option temperature protection of the power semiconductors
with monitoring output
• Mounting on DIN-rail
• As option with...
• AC semiconductor relay / -contactor
• According to IEC/EN 60947-4-3
• Load current up to 125 A, AC 51 with I2t up to 18000 A2s
• Switching at zero crossing
• As option switching at voltage maximum
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
•...
• AC solid-state relay / -contactor
• According to IEC/EN 60947-4-3
• As option load current up to 2 x 32 A or 2 x 48 A
• As option with hight I²t up to 6600 A²s
• Load voltages up to AC 480 V
• 2 anti-parallel thyristors for each pole
• DCB technology (direct bonding method) for excellent
heat transmission...
• AC solid-state relay / -contactor for pulse package control of heating systems
• Control input DC 4 … 20 mA
• According to IEC/EN 60947-4-2
• Nominal voltage AC 48 ... 480 V
• Load current 25A, 50 A, AC-51
• LED status indicator for control and failure
• Box terminals
• Degree of protection IP20
• As...
• AC solid-state relay /-contactor
• With integrated load circuit monitoring
• Settable load limit value
• According to IEC/EN 60947-4-3
• Load current 40 A, AC 51
• Switching at zero crossing
• 2 anti-parallel thyristors
• DCB technology (direct bonding method) for excellent
heat transmission properties
•...
• AC solid-state relay /-contactor with load current measurement
(runs value)
• Analogue output DC 0 ... 10 V
• According to IEC/EN 60947-4-3
• Nominal voltage up to AC 480 V
• Load current up to 45 A, AC-51
• Switching at zero crossing
• DCB technology (direct bonding method) for excellent
heat transmission properties
•...
• Three Phase AC solid-state contactor
• Meets generally the requirements of IEC/EN 60947-4-3
• Zero cross or immediate switching
• 2 anti-parallel thyristors for each pole
• Direct copper bonded (DCB) technology
• Self-lifting box contact terminals
• Peak reverse voltage up to ±1600Vp
• Wide range AC and DC...
Solid state contactors from DOLD have a long service life and are used everywhere that high switching frequencies and switching cycle are required.