• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• According to EN 50156-1 for furnaces
• Single channel or two-channel operation
• Output: max. 4 NO contacts
• AC 230 V model with galvanic separation
• LED indicator for channel 1 / 2 and state of operation
• Short circuit detection between terminal Y1 and common
• BG 5924 with:
- Removable terminal strips
- Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),
DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3
• BG 5924: width 22.5 mm
• IP 5924: width 70 mm
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508
• According to EN 50156-1 for furnaces
• Single channel or...
• For safety application up to PL e / Cat. 4 e.g. SIL 3
• Manual or automatic start
Function | Emergency stop module |
Cat. / PL according to EN ISO 13849-1 | 4/e |
SIL CL according to IEC/EN 62061 | 3 |
1- / 2-channel | 1; 2 |
Output contacts max. | 4 s |
Thermal current Ith max. | 5 A |
Nominal voltage DC | + |
Nominal voltage AC | + |
Nominal voltage AC/DC | + |
Approvals | UL-Recognized |
Connection | PS |
Width | 22,5 mm |
Type | BG 5924 |
Please select required language:
Datasheet / Operating Instructions, File: pdf, File size 2 MB
EPLAN Electric P8 Makro, BG 5924, File: zip, File size 433 KB
The emergency stop modules BG 5924 and IP 5924 can be used to protect people and machines by interrupting a safety circuit in a safe way.