Flasher

Flasher

Control of malfunction notifications and position lights

DOLD flasher relays are used on cranes, wind power systems as well as airfield lighting where they control position lighting. The control of malfunction notifications on machines, lighting, fans, et cetera is an additional task of these devices. Impulse time and pause time are identical with flasher relays.

Please select required language:

Catalogue, Time control technique, File: pdf, File size 4 MB

Choose a product:

Nominal voltage AC

Nominal voltage AC/DC

Nominal voltage DC

Output contacts

Enclosure design

Width

Approvals

Flasher relay MK 7851

• According to IEC/EN 61 812-1
• Adjustable flashing frequency, impulse time up to 300 s
• Repeat accuracy < ± 0.5 %
• Adjustable on absolute scale
• Start with impulse
• Available start with space
• Dual-voltage version
• LED indication for operation and contact position
• 2 changeover contacts
•...

Flasher relay BC 7932N

• Conformes à IEC/EN 61 812-1
• Fréquence clignotante réglable, durée d‘impulsion jusqu‘à 100 s
• Début par impulsion
• Précision de répétition ≤ 0,5 % + 10 ms
• Exécution bitension
• DEL pour visualisation de la position des contacts
•...

Flasher relay IK 7816

• According to IEC/EN 61 812-1
• Pulse time up to 100 s
• Adjustable flashing time
• Repeat accuracy ≤ 1 %
• Start with a pulse
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7816: depth 58 mm, with terminals at the bottom for
installation systems and...

Flasher relay RK 7816

• According to IEC/EN 61 812-1
• RK 7813, RK 7815, RK 7816: Time ranges up to 10 h
• RK 7814: 4 time ranges up to 16 h
• LED indicator for state of contact
• Dual-voltage-version AC 230 V + AC/DC 24 V or
AC 110 ... 127 V + AC/DC 24 V
• 1 changeover contact
• As option units with second changeover contact
(only for voltage...

Flasher relay SK 7816

• According to IEC/EN 61 812-1
• Pulse time up to 100 s
• Adjustable flashing time
• Repeat accuracy ≤ 1 %
• Start with a pulse
• LED indicator for contact position
• 1 changeover contact
• Devices available in 2 enclosure versions:
IK 7816: depth 58 mm, with terminals at the bottom for
installation systems and...

Flasher Relay BA 7981

• According to IEC/EN 61 812-1
• Impulse time up to 3 s settable
• Repeat accuracy < ± 3 %
• Setting on absolute scale
• Start with impulse
• LED display for operation and contact position
• Available with 1 or 2 changeover contacts, as well as
with semiconductor output
• Width 45 mm

Flasher relay, with manual mode IK 7827

• According to IEC/EN 61 812-1
• Pulse time up to 100 s
• IK 7827 start with pulse
• IK 7827/100 start with pause
• Repeat accuracy ≤ 0.5 % + 10 ms
• Pushbutton for manual actuation of the contact
• 1 changeover contact for 16 A
• Width 17.5 mm

More information

Flasher relays from DOLD for controlling automatic processes on machines, lighting, fans, et cetera.

Your contact


    Competence on site

    Damit wir für Sie Ihren persönlichen Ansprechpartner finden können, geben Sie bitte die fünfstellige Postleitzahl Ihres Ortes in das Suchfeld ein.

    Contact for: